START UP AND COMMISSIONING REPORT
| Equip. Type |
Air Compressor |
Air Dryer |
Filter (FE/FFG) |
Eco-Drain |
Air Receiver |
| Model |
BSD 75 T |
ABT 82 |
F 83 KF |
ED-31 (comp) |
/ |
| Part No |
BSD.4 |
1.4872.1 |
|
ED-31 (dryer) |
|
| Sr. No. |
2046 |
5520 |
|
|
|
| Mfg. Year |
2024 |
2024 |
|
|
|
| Run hrs. |
01 |
|
|
|
|
| Load Hrs. |
01 |
|
|
|
|
| Application |
|
|
|
|
|
Environment:
Clean / Average / Dusty
Location:
Indoor / Outdoor
Room Ventilation:
Good / Average / Poor
Exhaust Fan Installed:
Yes / No
Ducting Installed:
Yes / No
On Cooling Air Inlet:
Yes / No
On Cooling Air Outlet:
Yes / No
Flexible hose / Axial compensator installed at compressor Air outlet:
Yes / No
Isolation Valve Installed:
Yes / No
| Power Supply |
L1 |
L2 |
L3 |
Installed Fuse Rating |
| V |
A |
V |
A |
V |
A |
|
| Incoming Voltage |
404 |
|
405 |
|
404 |
|
125 A MCCB A |
| Full Load Current |
|
78 |
|
75 |
|
74 |
Supply Cable Size & type:
95 sq mm Copper Cable
O/L Relay Setting (B25):
50 A
Fan 2 MPCB Setting (F5):
- A
Fan 1 MPCB Setting (F4):
2.4 A
Control MPCB Setting (F11):
1.1 A
Logo Power DC Output:
24 V
Sigma Control Software Version:
6.3.3
Control Transformer Output Voltage:
24 V
Pressure Setting
SP: 10.0 Bar
SD: -0.5 Bar
| Air Dryer |
L1 |
L2 |
L3 |
Installed Fuse Rating |
| V |
A |
V |
A |
V |
A |
A |
| Incoming Voltage |
405 |
|
404 |
|
405 |
|
|
| Full Load Current |
|
2.0 |
|
2.2 |
|
2.1 |
|
Check Fan Motor Direction:
OK
Ref. comp. O/L Setting:
5.5 A
Fan Motor O/L Setting:
0.48 A
Check Dryer Inlet & Outlet Air piping Connected Correctly:
-
Check Bypass Arrangement Installed:
Yes / No
I acknowledge that above mentioned unit/units has/have been started in accordance to Kaeser recommendation & is/are functioning satisfactorily & is/are free from visible defects. I understand and undertake the responsibility to carry out proper operation and maintenance procedures as required. Failure in carrying out these procedures & using non-genuine spare parts will render the warranty void.
| Start of Work |
End of Work |
| 10:30 am |
04:30 pm |
| Travelling Time |
Travelling K.M. |
Technician Name |
| 01 hrs |
40 km |
M. Sivaram |
Work Done - Yes / No
M. Sivaram
9624590091
Service Engineer Sign & Name